{"id":25,"date":"2017-11-23T05:05:54","date_gmt":"2017-11-23T05:05:54","guid":{"rendered":"http:\/\/mdxlifesciences.com\/?page_id=25"},"modified":"2018-08-28T01:17:10","modified_gmt":"2018-08-28T01:17:10","slug":"technology","status":"publish","type":"page","link":"https:\/\/mdxlifesciences.com\/index.php\/technology\/","title":{"rendered":"Tissue Oxygen Balance &#8211; MDXVIEWER"},"content":{"rendered":"<h3>Patient Monitoring &#8211; The Challenge<\/h3>\n<p>Today, the monitoring devices in\u00a0 ORs and ICUs provide information <u><b>only<\/b><\/u> on the systemic respiratory and cardiovascular compartments.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-256\" src=\"http:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/OR_ICU.jpg\" alt=\"\" width=\"643\" height=\"239\" srcset=\"https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/OR_ICU.jpg 643w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/OR_ICU-300x112.jpg 300w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/OR_ICU-100x37.jpg 100w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/OR_ICU-360x134.jpg 360w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/p>\n<p>Monitoring of the microcirculation and cellular functions, at the tissue level, is a <strong><span style=\"text-decoration: underline;\">critical missing need<\/span><\/strong> in the daily patients\u2019 care. MDX\u00a0LIFESCIENCES developed an integrated system aiming to solve the problem<\/p>\n<h3>MDX LIFESCIENCES&#8217; Breakthrough Integrated Technology<\/h3>\n<p><b>MDX\u00a0LIFESCIENCES have a unique <\/b><b>device for real-time monitoring of mitochondrial <\/b><b>NADH for\u00a0<\/b><b>patients in critical care that was cleared by the FDA.<\/b><\/p>\n<p>Under body metabolic instability which might be developed in critically ill patients, blood flow redistribution will occur in order to protect the most vital organs, namely: Brain, Heart and adrenal medulla. MDX LIFESCIENCES&#8217; technology provides early warning signals of Microcirculatory and Mitochondrial dysfunction in combination with changes in Macrocirculatory and respiratory functions.<\/p>\n<p><img loading=\"lazy\" class=\"size-full wp-image-236 aligncenter\" src=\"http:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/oxygen_balance.jpg\" alt=\"\" width=\"681\" height=\"492\" srcset=\"https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/oxygen_balance.jpg 681w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/oxygen_balance-300x217.jpg 300w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/oxygen_balance-90x65.jpg 90w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/oxygen_balance-331x239.jpg 331w\" sizes=\"(max-width: 681px) 100vw, 681px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h3>Mitochondrial NADH<\/h3>\n<p>The function of the Human body is fully dependent on continuous supply of Oxygen originate from the atmospheric air, down the gradient in the body, into the intracellular organelles \u2013 the Mitochondria.\u00a0Mitochondria &#8211;The Intracellular \u201cNano\u201d Organells Providing Energy for Cellular Functions. The NADH molecule is a control marker in the energy generation chain in the mitochondria. MDX\u00a0LIFESCIENCES have a unique device for monitoring of mitochondrial NADH in patients that was cleared by the FDA.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-405\" src=\"http:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/NADH.jpg\" alt=\"\" width=\"587\" height=\"561\" srcset=\"https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/NADH.jpg 587w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/NADH-300x287.jpg 300w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/NADH-68x65.jpg 68w, https:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/NADH-250x239.jpg 250w\" sizes=\"(max-width: 587px) 100vw, 587px\" \/><\/p>\n<h3>MDXViewer<\/h3>\n<p>MDXViewer monitors are based on proprietary, patented technology for measuring key parameters of Tissue Metabolic Score continuously, simultaneously and in real-time with a single probe. MDXViewer simultaneously measures mitochondrial NADH, blood oxygenation, microcirculatory blood flow and tissue reflectance.<\/p>\n<p>Tissue viability depends on the balance between the oxygen supply to, and the oxygen demand by the body&#8217;s organs. Microcirculatory blood flow and volume as well as local blood oxygenation, represent the regulatory process of O2\u00a0supply and delivery to the tissue.<\/p>\n<p>An intracellular biological factor &#8211; mitochondrial NADH redox state &#8211; serves as marker of the energy generation process and oxygen balance in the cell. Imbalances in the energy regime will be translated into changes of the NADH levels. The optical technology used (MDXViewer) is based on continuous, real-time concurrent monitoring of four critical parameters from the same tissue volume by one single probe. These parameters: NADH redox state, microcirculatory blood flow, microcirculatory blood oxygenation and tissue reflectance are highly correlated to tissue viability and are translated to a new concept \u201cTissue Metabolic Score\u201d. For example the Urethral wall oxygen balance, representing the less vital organs, could be used as an indicator to the systemic overall metabolic homeostasis.<\/p>\n<p>The MDXViewer illuminates tissue by low power light and detects light that is subsequently emitted. The light is guided to the tissue by a bundle of flexible optical fibers and emitted from the tissue both by reflection and fluorescence. The emitted light is collected by a bundle of optical fibers that are combined in a proprietary probe. The detected optical signals are converted into electronic signals, which are in turn processed by the central-processing unit. The light emitted from the tissue is comprised of four separate components:<\/p>\n<ol>\n<li style=\"padding-left: 30px;\">A Doppler shifted reflected light, at the excitation wavelength, indicative of microcirculatory blood flow (TBF).<\/li>\n<li style=\"padding-left: 30px;\">Total back scattered or reflected light, correlated to blood volume at the observed tissue block.<\/li>\n<li style=\"padding-left: 30px;\">Fluorescence light, emitted by intracellular NADH, indicative of the cellular mitochondrial function and of the tissue&#8217;s metabolic state. This constitutes a novel marker for the energetic state of the tissue.<\/li>\n<li style=\"padding-left: 30px;\">Reflected light (at 2 specific wavelength) affected by the level of hemoglobin oxygenation at the microcirculation level.<\/li>\n<\/ol>\n<div align=\"left\">\n<hr \/>\n<h3><span class=\"PageSubTitle\"><span style=\"font-size: large;\">In-Vivo Tissue Spectroscopy<\/span><\/span><\/h3>\n<h3 align=\"center\"><\/h3>\n<p><center><br \/>\n<video src=\"http:\/\/mdxlifesciences.com\/wp-content\/uploads\/2017\/11\/In-vivio.mp4\" autoplay=\"autoplay\" loop=\"loop\" controls=\"controls\" width=\"80%\" height=\"automatic\"><\/video><\/center><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Patient Monitoring &#8211; The Challenge Today, the monitoring devices in\u00a0 ORs and ICUs provide information only on the systemic respiratory and cardiovascular compartments. Monitoring of the microcirculation and cellular functions, at the tissue level, is a critical missing need in the daily patients\u2019 care. MDX\u00a0LIFESCIENCES developed an integrated system aiming &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/pages\/25"}],"collection":[{"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/comments?post=25"}],"version-history":[{"count":99,"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/pages\/25\/revisions"}],"predecessor-version":[{"id":596,"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/pages\/25\/revisions\/596"}],"wp:attachment":[{"href":"https:\/\/mdxlifesciences.com\/index.php\/wp-json\/wp\/v2\/media?parent=25"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}